+62-21-344 2919      +62-21-3511 428      +62-811-9119-611   
    deltacrete@gmail.com      Senin - Jumat 9.00 - 17.00

Deltafloor CRC

High Chemical Resistant Epoxy Resin Floor Coating

DESCRIPTION

Deltafloor CRC high chemical epoxy resin floor coating is a that suitable for all kinds of manufacturing floor like storage and warehouses and processing areas.

USES

Deltafloor CRC is recommended to areas where chemical resistance and aesthetic aspects are required. Deltafloor CRC is recommended for use in floor of warehouses, industrial and food processing areas, kitchen, laboratory, engineering, workshops, and car parks.

ADVANTAGES

  • Impervious seamless and jointless surface
  • Easy to clean and maintain
  • Hygienic
  • Excellent chemical resistance

CONSUMPTION

Deltafloor CRC consumption is 450 gram/m2 for 300 mikron thickness and 700 gram/m2 for 500 mikron thickness. Please kindly contact Deltacrete to have appropriate technical assistance for the recommended thickness since material performance may vary at different surface.

INSTRUCTION FOR USE

For best performance of Deltafloor CRC, please kindly follow our recommendation. Preparation is a must before application. For new concrete, allow the concrete to cure at least 28 days. Humidity is not more than 75% measured in accordance with BS 8203. Since Deltafloor CRC is relatively thin coating, the substrate must be fine textured. Any substrate must be structurally sound, clean, dry, and free from all traces of loose material, laitance, oil and grease. Any unsound material must be removed before application. Preparation by captive blasting or diamond grinding is ideal for surface preparation. Deltafloor color pot should be mixed thoroughly with component A (enamel) first before mix them thoroughly using low speed drill and mixing paddle mixer. Continue mixing process until a consistence homogeneous mixture achieved, normally it needed 3-5 minutes. Apply the mixed Deltafloor CR onto prepared surface using a brush or roller. Ensure that the area is completely coated and that ‘ponding’ material does not occur. Apply the second coat as soon as the first coat is initially dried (typically 5-6 hours).

Cleaning

Tools and equipment should be cleaned immediately after use, while the mixture are still un-cured with solvent cleaner. When mixture already hardened, please kindly remove the material mechanically http://ukviagras.c.../.

CURING TIME (at 300 C)

Pot Life 20 minutes<
STT 5 – 6 hours
Initially hardness 24 hours
Fully Cured After 7 days

(ambient temperature may have some effect on the curing time)

TECHNICAL DATA

Form Liquid ( Component A and B)
Colour Component A = Colour ; Component B = Clear
Mix Density 1.2 – 1.3 kg/litre
Shelf Life 1 year when unopened and stored in dry conditions
Packaging 5.2 kg set (Component A+B+Color Pot)
Comp. A (Enamel) = 3.68 kg
Comp. B (Hardener)= 1.32 kg
Color Plot = 0.2 kg
Note : The reaction of epoxies commences immediately after the two components are mixed. This reaction is temperature related and so the curing time will be approximately halved by a 100 C increase in temeprature and doubled by a 100 C decrease in temperature. For sealing new or bare surfaces apply epoxy primer before top coat.

LIMITATIONS

Deltafloor CRC should not applied on the surface known to, or likely to suffer from, rising dampness, potential osmosis problems or have a relative humidity greater than 75%. If movement or cracking of the substrate takes place after application then reflective cracking of topping may occur. Ambient temperature when application is more than 100 C.

HEALTH AND SAFETY

Deltafloor range of products can cause skin irritations in persons with sensitive skin. Wear protective clothing like gloves, goggles and respiratory equipment, particularly in confined spaces. Ensure adequater ventilation and avoid inhalation of vapors. If splashed into the eyes, nose, mouth or throat, flush immediately with plenty of clean, warm water and seek medical attention without delay.

FIRE

Deltafloor CRC is flammable material. Keep it away from source of ignition. Smoking is not allowed during material application. In the event of fire, extinguish with CO2 or foam.

Our Location

PT. Deltacretindo Wira Mandiri
  JL. Pintu Air IV No. 41A
  Jakarta, Indonesia 10710
  +62-21-344 2919
  +62-21-3511 428
  +62-811-9119-611
   :  deltacrete@gmail.com

haki cm

© 2017 Deltacretindo. All Rights Reserved. Powered By GM-Portalindo